What is fire compartmentation?
It means dividing a building into fire-resisting sections to limit the spread of fire and smoke. Walls and floors form the boundaries; doors, glazing and service openings need suitable protection too. Fire stopping seals gaps and joints in those boundaries. The fire resistance needed depends on the building’s design and use.
Is a compartmentation survey the same as a fire risk assessment?
No. A fire risk assessment looks at fire hazards, people at risk and the precautions and management of the premises. A compartmentation survey examines the fire-resisting construction in more detail. Your assessor may recommend one where there are defects or uncertainty about concealed areas. Its findings should feed back into the assessment and action plan.
What will the fire stopping survey report include?
You receive annotated digital floor plans showing compartment lines and identified defects, with suggested repairs and priorities. Damper locations and obvious fire hazards are also noted; recording a damper’s location does not mean it has been tested. Indicative repair costs are available on request. The report should be read alongside its inspection boundaries and access limitations.
Will the survey open up walls or ceilings?
Opening up is not automatically included. Tell us about concealed areas, the access already available and any recommendation for an intrusive survey. The inspection method and arrangements for opening up and making good need to be settled before work starts. A visual inspection cannot establish the condition of construction hidden from view.
How much does a fire compartmentation survey cost?
The price depends on the building’s size and complexity, the areas to be inspected and how easily the surveyor can reach them. Existing drawings and records also affect the work involved. Send us the address, available floor plans and reason for the survey so we can discuss what is needed before a quotation is provided.
Is a compartmentation survey a legal requirement?
There is no blanket rule requiring every building to have a separate compartmentation survey. In premises covered by the Fire Safety Order in England and Wales, duties include assessing fire risk and maintaining relevant precautions in good repair. A specialist survey may be needed to investigate defects or establish the condition of fire separation. Scotland and Northern Ireland have separate legislation.
Are fire stopping repairs included?
No. This service provides a survey and recommendations. The report helps you brief a competent contractor for the repairs, which need a separate quotation. Discuss what evidence or further inspection will be needed to confirm the work has addressed the findings; receiving the initial survey report does not close those actions.