What is an AOV system?
AOV stands for automatic opening vent. An AOV system opens designated vents when activated, usually by smoke detection or a manual control, to let smoke escape. It can include windows or roof vents, actuators, detectors, a control panel and power supplies. The vents must operate in the sequence designed for the building; opening every vent together is not necessarily the right response.
Does every building need smoke ventilation?
No single arrangement applies to every building. The need for smoke ventilation and the type of system depend on the building’s use, layout and fire strategy, with the relevant building regulations and guidance considered by the designer. If a fire risk assessment identifies a concern, share the findings so the next step addresses the building as well as the equipment.
How often should AOV testing and servicing take place?
The schedule should distinguish routine checks by the building’s management team from specialist servicing. It depends on the system instructions and relevant guidance. The monthly checks required for high-rise residential buildings in England are additional to servicing; they do not automatically require a monthly contractor visit. We can discuss a maintenance plan after reviewing the equipment and records.
Can you maintain an AOV system installed by another company?
We can arrange an assessment for a maintenance takeover. The specialist needs to establish the equipment’s condition, how it should operate and whether parts and technical support are available. Send the system make and recent service reports. Any repairs or missing information that need attention before cover starts can then be identified.
What is the difference between natural and mechanical smoke ventilation?
Natural smoke ventilation uses vents or shafts to let smoke escape without extract fans. Mechanical smoke ventilation uses powered fans to move smoke. Both need a design suited to the building. Tell us which type is installed, or send the drawings if you are unsure, so we can confirm the specialist work needed.
Which standards apply to an AOV system?
BS 7346-8 covers planning, design, installation, commissioning and maintenance of smoke-control systems. The BS EN 12101 series addresses smoke and heat control equipment, including natural ventilators in Part 2. The applicable standards and building guidance depend on the design and components. A product certificate alone does not establish that the complete installation is suitable for your building.
What affects the cost of AOV installation or repairs?
The number and type of vents, controls, cable routes and access all affect the quotation. For existing systems, condition and the availability of compatible parts also matter. Roof access equipment, builders’ work or changes to connected systems may need pricing separately. Share the drawings or latest service report so the quotation can set out what is included.